Research

Research

82868 bookmarks
Newest
Investigation of clinically acceptable agreement between two methods of automatic measurement of limb occlusion pressure: a randomised trial | BMC Biomedical Engineering | Full Text
Investigation of clinically acceptable agreement between two methods of automatic measurement of limb occlusion pressure: a randomised trial | BMC Biomedical Engineering | Full Text
Background Development of automatic, pneumatic tourniquet technology and use of personalised tourniquet pressures has improved the safety and accuracy of surgical tourniquet systems. Personalisation of tourniquet pressure requires accurate measurement of limb occlusion pressure (LOP), which can be measured automatically through two different methods. The ‘embedded LOP’ method measures LOP using a dual-purpose tourniquet cuff acting as both patient sensor and pneumatic effector. The ‘distal LOP’ method measures LOP using a distal sensor applied to the patient’s finger or toe of the operating limb, using photoplethysmography to detect volumetric changes in peripheral blood circulation. The distal LOP method has been used clinically for many years; the embedded LOP method was developed recently with several advantages over the distal LOP method. While both methods have clinically acceptable accuracy in comparison to LOP measured using the manual Doppler ultrasound method, these two automatic methods have not been directly compared. The purpose of this study is to investigate if the embedded and distal methods of LOP measurement have clinically acceptable agreement. The differences in pairs of LOP measurement in the upper and lower limbs of 81 healthy individuals were compared using modified Bland and Altman analysis. In surgery, it is common for cuff pressure to deviate from the pressure setpoint due to limb manipulation. Surgical tourniquet systems utilise a ± 15 mmHg pressure alarm window, whereby if the cuff pressure deviates from the pressure setpoint by > 15 mmHg, an audiovisual alarm is triggered. Therefore, if the difference (bias) ± SE, 95% CI of the bias and SD of differences ± SE in LOP measurement between the embedded and distal methods were all within ±15 mmHg, this would demonstrate that the two methods have clinically acceptable agreement. Results LOP measurement using the embedded LOP method was − 0.81 ± 0.75 mmHg (bias ± standard error) lower than the distal LOP method. The 95% confidence interval of the bias was − 2.29 to 0.66 mmHg. The standard deviation of the differences ± standard error was 10.35 ± 0.49 mmHg. These results show that the embedded and distal methods of LOP measurement demonstrate clinically acceptable agreement. Conclusions The findings of this study demonstrate clinically acceptable agreement between the embedded and distal methods of LOP measurement. The findings support the use of the embedded LOP method of automatic LOP measurement using dual-purpose tourniquet cuffs to enable accurate, effective and simple prescription of personalised tourniquet cuff pressures in a clinical setting.
Investigation of clinically acceptable agreement between two methods of automatic measurement of limb occlusion pressure: a randomised trial | BMC Biomedical Engineering | Full Text
Rapid testing of red blood cell parameters in primary care patients using HemoScreen™ point of care instrument | BMC Primary Care | Full Text
Rapid testing of red blood cell parameters in primary care patients using HemoScreen™ point of care instrument | BMC Primary Care | Full Text
Background Patients with anemia are frequently encountered in primary care. Once anemia is detected, it is essential to define the type and identify the underlying cause prior to initiation of treatment. In most cases, the cause can be determined using information from the patient history, physical exam, and complete blood counts (CBC). Point of care testing of blood cell counts would speed up the work up of anemia patients. The aim of the present study was to evaluate if the HemoScreen™ instrument (PixCell Medical, Yokneam Ilit, Israel) could be used for primary care samples. It is a POCT instrument that utilizes single sample cuvettes and image analysis of full blood count including RBC, Hemoglobin, MCV, MCH, platelets, WBC, and WBC 5-part differential. Methods We compared the HemoScreen™ and the Sysmex XN instrument results of 100 primary care patient samples focusing on the total white blood cells, red blood cell parameters RBC, Hemoglobin, MCH, MCV and platelets. Results Deming correlations between the HemoScreen™ and the Sysmex XN instruments for the CBC were WBCHemoScreen™ = 1.016* WBCSysmex + 0.34; r = 0.981, RBCHemoScreen™ = 0.988* RBCSysmex + 0.015; r = 0.974, HemoglobinHemoScreen™ = 1.081* HemoglobinSysmex − 11.25; r = 0.964, MCHHemoScreen™ = 0.978* MCHSysmex + 0.78; r = 0.939, MCVHemoScreen™ = 0.963* MCVSysmex + 8.68; r = 0.946, PlateletsHemoScreen™ = 0.964* PlateletsSysmex + 25.7; r = 0.953. Conclusion The HemoScreen™ instrument could provide rapid and accurate test results for evaluation of the red blood cell parameters in primary care. This new technology is interesting as it allows the analysis red blood cell parameters also at small primary care centers.
Rapid testing of red blood cell parameters in primary care patients using HemoScreen™ point of care instrument | BMC Primary Care | Full Text
‘A false sense of security’: Experts say delta-8 THC products can still be dangerous | CNN
‘A false sense of security’: Experts say delta-8 THC products can still be dangerous | CNN
Products containing the cannabis compound delta-8 are sometimes marketed as “diet weed” or “light THC,” offering a milder high than what people probably think is in traditional weed products. But the drug can still be dangerous, and an increasing number of users are calling poison centers for help.
‘A false sense of security’: Experts say delta-8 THC products can still be dangerous | CNN
US5116312A - Method and apparatus for automatic autotransfusion - Google Patents
US5116312A - Method and apparatus for automatic autotransfusion - Google Patents
A method and system for closed-loop, automated, closed, autotransfusion having a computer in electronic communication with a bedside monitor, an infusion pump, wherein the infusion pump is controlled by the computer, a blood collection canister for receiving shed mediastinal blood from a patient, means for filtering the blood, means for transferring the blood from the canister to the infusion pump and then into the patient, means for automatically taking a set of time-spaced measurements of a hemodynamic variable of the patient wherein the hemodynamic variable is coded into a multiplicity of digitally coded signals that are transmitted to the computer, and programming means for analysis of the digitally coded signals to determine the rate of the infusion pump, wherein the blood is infused at a high rate intermittently.
US5116312A - Method and apparatus for automatic autotransfusion - Google Patents
TECO® Cyprinid Vitellogenin ELISA - Diapharma
TECO® Cyprinid Vitellogenin ELISA - Diapharma
The TECO® Cyprinid Vitellogenin ELISA kit is a sensitive assay for the quantitative determination of vitellogenin in serum, WBH and mucus of cyprinids.
TECO® Cyprinid Vitellogenin ELISA - Diapharma
ABS2 Sampler | Automated Blood Sampler | Instech Laboratories
ABS2 Sampler | Automated Blood Sampler | Instech Laboratories
Automate the collection of blood sampling in laboratory animals with teh ABS2. Eliminate labor-intesive manual withdrawals, increase accuracy, and increase the throughput of your pharmacokinetic research. Learn more.
ABS2 Sampler | Automated Blood Sampler | Instech Laboratories
The Different Types of Blood Collection Devices | BioTouch
The Different Types of Blood Collection Devices | BioTouch
Blood collection is a fundamental process in medical diagnostics, research, and treatment. The effectiveness and accuracy of diagnostic tests often depend on the quality of the blood sample collected. At BioTouch Global, we understand the critical
The Different Types of Blood Collection Devices | BioTouch
Blood self-sampling devices: innovation, interpretation and implementation in total lab automation
Blood self-sampling devices: innovation, interpretation and implementation in total lab automation
The introduction of the vacuum tube in 1949 revolutionized blood collection, significantly improving sample quality and patient comfort. Over the past 75 years, laboratory diagnostics have evolved drastically, from manual to automated processes, reducing required test volumes by over 1,000 times. Despite these advancements, venous blood collection presents logistical challenges, including centralized scheduling and a large volume of biological waste due to the imbalance between the needed blood volume (often very little) and the collected volume (often in excess). The COVID-19 pandemic further emphasized the need for decentralized healthcare solutions and patient empowerment. Capillary blood collection, widely used in point-of-care testing, offers a promising alternative, particularly for patients facing frequently, or difficulties with, venous sampling. The Leiden University Medical Center in the Netherlands experienced a 15 % reduction in volume of laboratory tests during and after the pandemic, attributed to patient preference for local blood collection and testing. To address these challenges, self-sampling devices are emerging, empowering patients and streamlining sample logistics. However, challenges such as cost, transportation regulations, and sample volume adequacy persists. Robust devices tailored for total lab automation and sustainable practices are crucial for widespread adoption. Despite hurdles, the integration of self-sampling into diagnostic processes is inevitable, heralding a shift towards patient-centered, proactive healthcare. Practical recommendations include robust device design, ease of use, affordability, sustainability, sufficient quality and acceptability by seamless integration into laboratory workflows. Although obstacles remain, self-sampling represents the future of laboratory diagnostics, offering convenience, cost-effectiveness, interoperability and patient empowerment.
Blood self-sampling devices: innovation, interpretation and implementation in total lab automation
Maximizing Microsampling: Measurement of Comprehensive Metabolic and Lipid Panels Using a Novel Capillary Blood Collection Device | The Journal of Applied Laboratory Medicine | Oxford Academic
Maximizing Microsampling: Measurement of Comprehensive Metabolic and Lipid Panels Using a Novel Capillary Blood Collection Device | The Journal of Applied Laboratory Medicine | Oxford Academic
AbstractBackground. Demand continues to grow for patient-centric sampling solutions that enable collection of small volumes of blood outside of healthcare
Maximizing Microsampling: Measurement of Comprehensive Metabolic and Lipid Panels Using a Novel Capillary Blood Collection Device | The Journal of Applied Laboratory Medicine | Oxford Academic
Remote Neuronal Activation Coupled with Automated Blood Sampling to Induce and Measure Circulating Luteinizing Hormone in Mice - PMC
Remote Neuronal Activation Coupled with Automated Blood Sampling to Induce and Measure Circulating Luteinizing Hormone in Mice - PMC
Circulating luteinizing hormone (LH) levels are an essential index of the functioning of the hypothalamic-pituitary control of reproduction. The role of numerous inputs and neuronal populations in the modulation of LH release is still unknown. ...
Remote Neuronal Activation Coupled with Automated Blood Sampling to Induce and Measure Circulating Luteinizing Hormone in Mice - PMC
Research on Finger Vein Image Segmentation and Blood Sampling Point Location in Automatic Blood Collection
Research on Finger Vein Image Segmentation and Blood Sampling Point Location in Automatic Blood Collection
In the fingertip blood automatic sampling process, when the blood sampling point in the fingertip venous area, it will greatly increase the amount of bleeding without being squeezed. In order to accurately locate the blood sampling point in the venous area, we propose a new finger vein image segmentation approach basing on Gabor transform and Gaussian mixed model (GMM). Firstly, Gabor filter parameter can be set adaptively according to the differential excitation of image and we use the local binary pattern (LBP) to fuse the same-scale and multi-orientation Gabor features of the image. Then, finger vein image segmentation is achieved by Gabor-GMM system and optimized by the max flow min cut method which is based on the relative entropy of the foreground and the background. Finally, the blood sampling point can be localized with corner detection. The experimental results show that the proposed approach has significant performance in segmenting finger vein images which the average accuracy of segmentation images reach 91.6%.
Research on Finger Vein Image Segmentation and Blood Sampling Point Location in Automatic Blood Collection
Tip of the iceberg: erectile dysfunction and COVID-19 - PMC
Tip of the iceberg: erectile dysfunction and COVID-19 - PMC
The novel severe acute respiratory syndrome coronavirus 2 caused the coronavirus 2019 (COVID-19) pandemic that resulted in more than 150 million infections and 3.5 million deaths globally. COVID-19 affected men more than women, emerging with more ...
Tip of the iceberg: erectile dysfunction and COVID-19 - PMC
European Association of Urology Guidelines on Sexual and Reproductive Health-2021 Update: Male Sexual Dysfunction - PubMed
European Association of Urology Guidelines on Sexual and Reproductive Health-2021 Update: Male Sexual Dysfunction - PubMed
Updated European Association of Urology guidelines on sexual and reproductive health are presented, addressing the diagnosis and treatment of the most prevalent conditions in men. Patients must be fully informed of all relevant diagnostic and therapeutic options and, together with their treating phy …
European Association of Urology Guidelines on Sexual and Reproductive Health-2021 Update: Male Sexual Dysfunction - PubMed